Types of Roof vents (Exhaust) and Intake Vents

The Edge Vent

Air Vent, the industry leader in residential attic ventilation has a shingle-over, edge-of-roof installed intake vent – The Edge™Vent. It not only provides continuous intake airflow at the roof’s edge but it significantly simplifies intake vent installation by keeping the roofing contractor on the roof.

 

 

ShingleVent II (Ridge Vent)

ShingleVent® II ridge vent installs on the peak of the roof allowing exhaust ventilation all along the roofline — end-to-end.

ShingleVent II ridge vent has a low profile, shingle-over design that blends in with the roof. Once installed ShingleVent II provides exceptional attic ventilation and is almost invisible from the ground.

Roof Louvers (Static Vent) Slant-Back Metal Roof Vent 

RVG55 Slant Galvanized, Pre Painted Steel
•Heavy-duty galvanized construction
•NFA (square inches): 50/pc.
•9″ round opening

 

Maximum Ventilation VMAX-301

Adjustable sloped flashing from 2/12 to 15/12
Suggested ventilation area: 1000 to 1200ft2.

Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations, even withstanding hurricane wind and rain conditions of 175 km./hr. or 110 mi/hr. Its unique storm proof system prevents infiltrations, while at the same time capturing the wind from all directions and at velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney effect” results in drawing the stale air and moisture out of the attic space, while replacing it with fresh new air that enters through the soffits.

The model VMAX-301-12 has been designed for slope roof application and is compatible with most all types of roofing membrane including metal. It has no moving parts, requires no electricity, and is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations without being covered, thus, finally giving the home owner a peace of mind.

Model : VMAX-301-12
Deflectors : 4
Net Free Evacuation : 144 in.2
Tested Extraction Rate : 418 CFM
Suggested Ventilation Area : 1000 to 1200 ft.2
Adjustable Flashing : 2/12 to 15/12
Storm Proof : Unique precision engineered deflector system
Solid : Built of galvanized steel
Standard Gauge : 24 & 26
Rodent Proof : Built-in galvanized wire mesh screen
Finish : Interior and exterior powder coated polyester baked paint with UV protection
Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion
Compliances : CSA, CAN-3-A930M82, ASTM-527, Miami Dade approved, ICC-ES

 

Maximum Ventilation VMAX-302

Adjustable sloped flashing from 2/12 to 15/12
Suggested ventilation area: 400 to 500 ft2.

Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind from all directions and at velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney effect” results in drawing the stale air and moisture out of the attic space, while replacing it with fresh new air that enters through the soffits.

The model VMAX-302-12 has been designed for slope roof application and is compatible with most all types of roofing membrane including metal. It has no moving parts, requires no electricity, and is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations without being covered, thus, finally giving the home owner a peace of mind.

Model : VMAX-302-8
Deflector : 1
Net Free Evacuation : 64 in.2
Suggested Ventilation Area : 50 to 250 ft.2
Adjustable Flashing : 2/12 to 7/12
Storm Proof : Unique precision engineered deflector system
Solid : Built of galvanized steel
Standard Gauge : 24 & 26
Rodent Proof : Built-in galvanized wire mesh screen
Finish : Interior and exterior powder coated polyester baked paint with UV protection
Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion
Compliances : CSA, CAN-3-A930M82, ASTM-527

Maximum Ventilation VMAX-CT-4 Exhaust Vent (Bathroom Vent)

Dimension : Built-in 4 in. diameter tail pipe
Height : 73/4 in.
Width : 51/4 in.
Roof Pitch : 2/12 to 15/12
Storm Proof : Unique precision engineered storm proof system
Solid : Structural quality galvanized steel
Rodent Proof : Removable galvanized wire mesh grill
Finish : Powder coated polyester baked paint with UV protection
Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion